Density CalculatorMeasure mass. Define volume.

Density calculators / Soils, powders & packing

A clear measure of matter.

Zero Air Voids Density Calculator

Calculate the theoretical saturated zero-air-voids dry-density limit at a stated water content.

Your measurements & units

kg/m³
%

Starting values are editable examples. Confirm the sample, measurement basis and units. Dimension switching converts only the labelled geometry fields; other unit selectors describe the numbers you enter.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

ρdry,ZAV=Gs ρwater/(1+w Gs).

Calculate the theoretical saturated zero-air-voids dry-density limit at a stated water content.

  1. Confirm the sample, reference state, measurement basis and units.
  2. Enter actual measurements and compatible reference values.
  3. Submit the form, then interpret the result with the assumptions and limits below.

This algebraic limit is not the laboratory maximum dry density or optimum moisture content. Actual compaction needs measured curve data.

Zero Air Voids Density: method and interpretation

Calculate the theoretical saturated zero-air-voids dry-density limit at a stated water content. This algebraic limit is not the laboratory maximum dry density or optimum moisture content. Actual compaction needs measured curve data.

Dry bulk density includes pore volume and excludes water mass; particle density excludes the spaces between solid particles. These quantities cannot be exchanged in porosity, slurry or phase-relationship equations without changing the meaning.

Soil relative density, relative compaction, zero-air-voids density and maximum laboratory dry density are different concepts. Powder tapping also depends on a stated test method. No acceptance limits or complete testing procedure are selected by these numerical tools.

Check the numbers

Zero Air Voids Density Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Solid specific gravity = 2.65 ; Water density = 1000 kg/m³; Dry-basis water content = 15 %.

OutputComputed result
Theoretical zero-air-voids dry density1,896.243292 kg/m³
Mass density1.896243 g/cm³ or g/mL
Mass density118.378601 lb/ft³
Mass density0.068506 lb/in³
Mass density15.824917 lb/US gal
Mass density19.004933 lb/Imperial gal

How the stated input changes the result

ScenarioChanged input / basisResult
7.5 %Dry-basis water content2,210.636079 kg/m³
11.25 %Dry-basis water content2,041.405874 kg/m³
15 %Dry-basis water content1,896.243292 kg/m³
18.75 %Dry-basis water content1,770.354906 kg/m³
22.5 %Dry-basis water content1,660.140955 kg/m³
30 %Dry-basis water content1,476.32312 kg/m³

Unchanged inputs use: Solid specific gravity = 2.65 ; Water density = 1000 kg/m³; Dry-basis water content = 15 %. Results retain the model limitations described above.

Common questions

What measurement or model limitation matters here?

This algebraic limit is not the laboratory maximum dry density or optimum moisture content. Actual compaction needs measured curve data.

How are the example tables calculated?

Each row changes the labelled dry-basis water content while retaining the other worked-example inputs. The table uses the same ρdry,ZAV=Gs ρwater/(1+w Gs). calculation as the form.

How do I use this zero air voids density calculator?

Calculate the theoretical saturated zero-air-voids dry-density limit at a stated water content. ρdry,ZAV=Gs ρwater/(1+w Gs).

Which units should I enter?

Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.

Are starting values measured material or reference data?

They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.

Can I export the result to Excel?

After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.

Where are the formula sources?

Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • FHWA NHI-05-037: Chapter 5, soil phase relationships and relative densityhttps://www.fhwa.dot.gov/engineering/geotech/pubs/05037/05a.cfm
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors