Water Density at Temperature Calculator

Calculate pure reference-water density with the Tanaka temperature relation.

Your measurements & units

°C

Starting values are editable examples. Confirm the sample, measurement basis and units. Dimension switching converts only the labelled geometry fields; other unit selectors describe the numbers you enter.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

ρ=999.974950[1−(t−3.983035)²(t+301.797)/(522528.9(t+69.34881))].

Calculate pure reference-water density with the Tanaka temperature relation.

  1. Confirm the sample, reference state, measurement basis and units.
  2. Enter actual measurements and compatible reference values.
  3. Submit the form, then interpret the result with the assumptions and limits below.

0–40°C at 101325 Pa for air-free reference water. No salinity, high-pressure, steam, dissolved-solute or supercritical model.

Water Density at Temperature: method and interpretation

Calculate pure reference-water density with the Tanaka temperature relation. 0–40°C at 101325 Pa for air-free reference water. No salinity, high-pressure, steam, dissolved-solute or supercritical model.

Gas density changes with absolute pressure, absolute temperature, composition and nonideal behavior. Gauge pressure must first be converted using the actual atmospheric reference. A supplied compressibility factor is not automatically a real-gas property calculation.

Standard atmosphere describes a reference profile rather than observed weather. Water and moist-air equations have explicit temperature and pressure boundaries. Cryogenic liquids, steam tables, salinity and supercritical properties cannot be inferred from an ideal-gas or pure-water relation.

Check the numbers

Water Density at Temperature Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Water temperature = 20 °C.

OutputComputed result
Tanaka pure reference-water density998.206746 kg/m³
Reference pressure101.325 kPa absolute
Temperature20 °C
Mass density0.998207 g/cm³ or g/mL
Mass density62.316011 lb/ft³
Mass density0.036063 lb/in³
Mass density8.330439 lb/US gal
Mass density10.00444 lb/Imperial gal

How the stated input changes the result

ScenarioChanged input / basisResult
10 °CWater temperature999.702702 kg/m³
15 °CWater temperature999.102572 kg/m³
20 °CWater temperature998.206746 kg/m³
25 °CWater temperature997.047022 kg/m³
30 °CWater temperature995.648797 kg/m³
40 °CWater temperature992.215209 kg/m³

Unchanged inputs use: Water temperature = 20 °C. Results retain the model limitations described above.

Common questions

Can I calculate salt water density or density at high pressure?

This page is limited to pure reference water at 101325 Pa. Salinity, solute composition and high pressure need additional state-property equations.

Is water always exactly 1 g/mL?

No. The Tanaka relation varies with temperature and has a density maximum near 3.983°C under its stated reference conditions. The printed table illustrates the temperature dependence.

How do I use this water density at temperature calculator?

Calculate pure reference-water density with the Tanaka temperature relation. ρ=999.974950[1−(t−3.983035)²(t+301.797)/(522528.9(t+69.34881))].

Which units should I enter?

Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.

Are starting values measured material or reference data?

They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.

Can I export the result to Excel?

After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.

Where are the formula sources?

Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • EURAMET Calibration Guide 19, version 4.1, equation 2: Tanaka water-density coefficients; download from official guidelines listhttps://www.euramet.org/publications-media-centre/calibration-guidelines
  • NIST, Harvey et al.: The Thermodynamic Properties of Water and Steam; discussion of CIPM/Tanaka 0–40°C density recommendationhttps://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=935265
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors