Water Density at Temperature Calculator
Calculate pure reference-water density with the Tanaka temperature relation.
Your measurements & units
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
ρ=999.974950[1−(t−3.983035)²(t+301.797)/(522528.9(t+69.34881))].
Calculate pure reference-water density with the Tanaka temperature relation.
- Confirm the sample, reference state, measurement basis and units.
- Enter actual measurements and compatible reference values.
- Submit the form, then interpret the result with the assumptions and limits below.
0–40°C at 101325 Pa for air-free reference water. No salinity, high-pressure, steam, dissolved-solute or supercritical model.
Water Density at Temperature: method and interpretation
Calculate pure reference-water density with the Tanaka temperature relation. 0–40°C at 101325 Pa for air-free reference water. No salinity, high-pressure, steam, dissolved-solute or supercritical model.
Gas density changes with absolute pressure, absolute temperature, composition and nonideal behavior. Gauge pressure must first be converted using the actual atmospheric reference. A supplied compressibility factor is not automatically a real-gas property calculation.
Standard atmosphere describes a reference profile rather than observed weather. Water and moist-air equations have explicit temperature and pressure boundaries. Cryogenic liquids, steam tables, salinity and supercritical properties cannot be inferred from an ideal-gas or pure-water relation.
Continue with: Ideal Gas Density Calculator · Air Density Calculator · Hydrogen Gas Density Calculator · Nitrogen Gas Density Calculator
Check the numbers
Water Density at Temperature Calculator: calculated examples
These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.
Worked example with stated inputs
Water temperature = 20 °C.
| Output | Computed result |
|---|---|
| Tanaka pure reference-water density | 998.206746 kg/m³ |
| Reference pressure | 101.325 kPa absolute |
| Temperature | 20 °C |
| Mass density | 0.998207 g/cm³ or g/mL |
| Mass density | 62.316011 lb/ft³ |
| Mass density | 0.036063 lb/in³ |
| Mass density | 8.330439 lb/US gal |
| Mass density | 10.00444 lb/Imperial gal |
How the stated input changes the result
| Scenario | Changed input / basis | Result |
|---|---|---|
| 10 °C | Water temperature | 999.702702 kg/m³ |
| 15 °C | Water temperature | 999.102572 kg/m³ |
| 20 °C | Water temperature | 998.206746 kg/m³ |
| 25 °C | Water temperature | 997.047022 kg/m³ |
| 30 °C | Water temperature | 995.648797 kg/m³ |
| 40 °C | Water temperature | 992.215209 kg/m³ |
Unchanged inputs use: Water temperature = 20 °C. Results retain the model limitations described above.
Common questions
Can I calculate salt water density or density at high pressure?
This page is limited to pure reference water at 101325 Pa. Salinity, solute composition and high pressure need additional state-property equations.
Is water always exactly 1 g/mL?
No. The Tanaka relation varies with temperature and has a density maximum near 3.983°C under its stated reference conditions. The printed table illustrates the temperature dependence.
How do I use this water density at temperature calculator?
Calculate pure reference-water density with the Tanaka temperature relation. ρ=999.974950[1−(t−3.983035)²(t+301.797)/(522528.9(t+69.34881))].
Which units should I enter?
Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.
Are starting values measured material or reference data?
They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.
Can I export the result to Excel?
After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.
Where are the formula sources?
Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.
- EURAMET Calibration Guide 19, version 4.1, equation 2: Tanaka water-density coefficients; download from official guidelines listhttps://www.euramet.org/publications-media-centre/calibration-guidelines
- NIST, Harvey et al.: The Thermodynamic Properties of Water and Steam; discussion of CIPM/Tanaka 0–40°C density recommendationhttps://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=935265
- NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors