Density calculators / Soils, powders & packing
A clear measure of matter.
Tapped and Bulk Powder Density Calculator
Calculate powder bulk/tapped density, Carr index and Hausner ratio from supplied test measurements.
Your measurements & units
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
ρbulk=m/Vloose; ρtapped=m/Vtapped; Carr=100(1−Vtapped/Vloose); Hausner=Vloose/Vtapped.
Calculate powder bulk/tapped density, Carr index and Hausner ratio from supplied test measurements.
- Confirm the sample, reference state, measurement basis and units.
- Enter actual measurements and compatible reference values.
- Submit the form, then interpret the result with the assumptions and limits below.
Same powder mass, positive final volume no greater than initial. No flow-quality category, true particle density or claim of complete current USP test compliance.
Tapped and Bulk Powder Density: method and interpretation
Calculate powder bulk/tapped density, Carr index and Hausner ratio from supplied test measurements. Same powder mass, positive final volume no greater than initial. No flow-quality category, true particle density or claim of complete current USP test compliance.
Dry bulk density includes pore volume and excludes water mass; particle density excludes the spaces between solid particles. These quantities cannot be exchanged in porosity, slurry or phase-relationship equations without changing the meaning.
Soil relative density, relative compaction, zero-air-voids density and maximum laboratory dry density are different concepts. Powder tapping also depends on a stated test method. No acceptance limits or complete testing procedure are selected by these numerical tools.
Continue with: Soil Dry Bulk Density Calculator · Wet to Dry Density Calculator · Dry to Wet Density Calculator · Soil Porosity from Density Calculator
Check the numbers
Tapped and Bulk Powder Density Calculator: calculated examples
These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.
Worked example with stated inputs
Powder mass = 100 g; Initial loose bulk volume = 200 mL; Final tapped volume = 160 mL.
| Output | Computed result |
|---|---|
| Loose bulk powder density | 500 kg/m³ |
| Tapped density | 625 kg/m³ |
| Carr compressibility index | 20 % |
| Hausner ratio | 1.25 |
| Mass density | 0.5 g/cm³ or g/mL |
| Mass density | 31.21398 lb/ft³ |
| Mass density | 0.018064 lb/in³ |
| Mass density | 4.172702 lb/US gal |
| Mass density | 5.011206 lb/Imperial gal |
How the stated input changes the result
| Scenario | Changed input / basis | Result |
|---|---|---|
| 50 g | Powder mass | 250 kg/m³ |
| 75 g | Powder mass | 375 kg/m³ |
| 100 g | Powder mass | 500 kg/m³ |
| 125 g | Powder mass | 625 kg/m³ |
| 150 g | Powder mass | 750 kg/m³ |
| 200 g | Powder mass | 1,000 kg/m³ |
Unchanged inputs use: Powder mass = 100 g; Initial loose bulk volume = 200 mL; Final tapped volume = 160 mL. Results retain the model limitations described above.
Common questions
What measurement or model limitation matters here?
Same powder mass, positive final volume no greater than initial. No flow-quality category, true particle density or claim of complete current USP test compliance.
How are the example tables calculated?
Each row changes the labelled powder mass while retaining the other worked-example inputs. The table uses the same ρbulk=m/Vloose; ρtapped=m/Vtapped; Carr=100(1−Vtapped/Vloose); Hausner=Vloose/Vtapped. calculation as the form.
How do I use this tapped and bulk powder density calculator?
Calculate powder bulk/tapped density, Carr index and Hausner ratio from supplied test measurements. ρbulk=m/Vloose; ρtapped=m/Vtapped; Carr=100(1−Vtapped/Vloose); Hausner=Vloose/Vtapped.
Which units should I enter?
Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.
Are starting values measured material or reference data?
They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.
Can I export the result to Excel?
After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.
Where are the formula sources?
Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.
- USP harmonization: Bulk Density and Tapped Density of Powders, chapter 616https://www.usp.org/sites/default/files/usp/document/harmonization/gen-chapter/bulk_density.pdf
- USP harmonization: Methods for Compressibility Index and Hausner Ratiohttps://www.usp.org/sites/default/files/usp/document/harmonization/gen-chapter/20230428HSm99885.pdf
- NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors