Density CalculatorMeasure mass. Define volume.

Density calculators / Statistics & distributions

A clear measure of matter.

Noise Spectral Density Calculator

Integrate a flat one-sided voltage power spectral density over a stated frequency band.

Your measurements & units

V²/Hz
Hz
Hz

Starting values are editable examples. Confirm the sample, measurement basis and units. Dimension switching converts only the labelled geometry fields; other unit selectors describe the numbers you enter.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Mean-square voltage=PSD × bandwidth; Vrms=√(mean square); ASD=√PSD.

Integrate a flat one-sided voltage power spectral density over a stated frequency band.

  1. Confirm the sample, reference state, measurement basis and units.
  2. Enter actual measurements and compatible reference values.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Flat voltage PSD only. No FFT, window correction, cross spectrum or arbitrary signal estimate. A PSD in W/Hz integrates to watts, not voltage RMS.

Noise Spectral Density: method and interpretation

Integrate a flat one-sided voltage power spectral density over a stated frequency band. Flat voltage PSD only. No FFT, window correction, cross spectrum or arbitrary signal estimate. A PSD in W/Hz integrates to watts, not voltage RMS.

A continuous probability density is a height in reciprocal variable units. Probability is an integral over an interval; a density may exceed one without violating probability rules. Histogram frequency density uses a count-per-class-width convention unless it is explicitly normalized.

Choose a distribution and parameters justified by the data. This page evaluates only its stated model, without fitting an arbitrary function. Spectral density has a separate frequency denominator and requires an explicit one-sided or two-sided convention before integration.

Check the numbers

Noise Spectral Density Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Constant one-sided voltage PSD = 1e-12 V²/Hz; Band lower frequency = 0 Hz; Band upper frequency = 10000 Hz.

OutputComputed result
Flat one-sided band RMS voltage0.0001 V RMS
Integrated mean square1.0e-8 V²
Amplitude spectral density1.0e-6 V/√Hz
Bandwidth10,000 Hz

How the stated input changes the result

ScenarioChanged input / basisResult
5e-13 V²/HzConstant one-sided voltage PSD7.071068e-5 V RMS
7.5e-13 V²/HzConstant one-sided voltage PSD8.660254e-5 V RMS
1e-12 V²/HzConstant one-sided voltage PSD0.0001 V RMS
1.25e-12 V²/HzConstant one-sided voltage PSD0.000112 V RMS
1.5e-12 V²/HzConstant one-sided voltage PSD0.000122 V RMS
2e-12 V²/HzConstant one-sided voltage PSD0.000141 V RMS

Unchanged inputs use: Constant one-sided voltage PSD = 1e-12 V²/Hz; Band lower frequency = 0 Hz; Band upper frequency = 10000 Hz. Results retain the model limitations described above.

Common questions

What measurement or model limitation matters here?

Flat voltage PSD only. No FFT, window correction, cross spectrum or arbitrary signal estimate. A PSD in W/Hz integrates to watts, not voltage RMS.

How are the example tables calculated?

Each row changes the labelled constant one-sided voltage psd while retaining the other worked-example inputs. The table uses the same Mean-square voltage=PSD × bandwidth; Vrms=√(mean square); ASD=√PSD. calculation as the form.

How do I use this noise spectral density calculator?

Integrate a flat one-sided voltage power spectral density over a stated frequency band. Mean-square voltage=PSD × bandwidth; Vrms=√(mean square); ASD=√PSD.

Which units should I enter?

Use the specific units printed beside each field. The resulting ratio, score or concentration has the meaning stated in the formula; it is not interchangeable with material mass density. Reference quantities and measurement conventions must match.

Are starting values measured material or reference data?

They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.

Can I export the result to Excel?

After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.

Where are the formula sources?

Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • MathWorks Signal Processing Toolbox: Spectral Analysishttps://www.mathworks.com/help/signal/ug/spectral-analysis.html
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors