Density CalculatorMeasure mass. Define volume.

Density calculators / Statistics & distributions

A clear measure of matter.

Uniform Probability Density Calculator

Evaluate the stated continuous probability density function at a supplied x.

Your measurements & units

input units
input units
input units

Starting values are editable examples. Confirm the sample, measurement basis and units. Dimension switching converts only the labelled geometry fields; other unit selectors describe the numbers you enter.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

f(x)=1/(b−a) inside [a,b], zero outside.

Evaluate the stated continuous probability density function at a supplied x.

  1. Confirm the sample, reference state, measurement basis and units.
  2. Enter actual measurements and compatible reference values.
  3. Submit the form, then interpret the result with the assumptions and limits below.

A PDF is in reciprocal input units and can exceed one. It is not P(X=x), which is zero for a continuous distribution. No arbitrary expression parser or joint-distribution model. All parameters must describe the chosen distribution.

Uniform Probability Density: method and interpretation

Evaluate the stated continuous probability density function at a supplied x. A PDF is in reciprocal input units and can exceed one. It is not P(X=x), which is zero for a continuous distribution. No arbitrary expression parser or joint-distribution model. All parameters must describe the chosen distribution.

A continuous probability density is a height in reciprocal variable units. Probability is an integral over an interval; a density may exceed one without violating probability rules. Histogram frequency density uses a count-per-class-width convention unless it is explicitly normalized.

Choose a distribution and parameters justified by the data. This page evaluates only its stated model, without fitting an arbitrary function. Spectral density has a separate frequency denominator and requires an explicit one-sided or two-sided convention before integration.

Check the numbers

Uniform Probability Density Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Evaluation x = 0.5 input units; Lower bound a = 0 input units; Upper bound b = 1 input units.

OutputComputed result
Uniform probability density at x1 1/input unit
CDF at x0.5 probability

How the stated input changes the result

ScenarioChanged input / basisResult
-0.5 input unitsEvaluation x0 1/input unit
0 input unitsEvaluation x1 1/input unit
0.25 input unitsEvaluation x1 1/input unit
0.5 input unitsEvaluation x1 1/input unit
1 input unitsEvaluation x1 1/input unit
1.5 input unitsEvaluation x0 1/input unit

Unchanged inputs use: Evaluation x = 0.5 input units; Lower bound a = 0 input units; Upper bound b = 1 input units. Results retain the model limitations described above.

Common questions

What measurement or model limitation matters here?

A PDF is in reciprocal input units and can exceed one. It is not P(X=x), which is zero for a continuous distribution. No arbitrary expression parser or joint-distribution model. All parameters must describe the chosen distribution.

How are the example tables calculated?

Each row changes the labelled evaluation x while retaining the other worked-example inputs. The table uses the same f(x)=1/(b−a) inside [a,b], zero outside. calculation as the form.

How do I use this uniform probability density calculator?

Evaluate the stated continuous probability density function at a supplied x. f(x)=1/(b−a) inside [a,b], zero outside.

Which units should I enter?

Use the specific units printed beside each field. The resulting ratio, score or concentration has the meaning stated in the formula; it is not interchangeable with material mass density. Reference quantities and measurement conventions must match.

Are starting values measured material or reference data?

They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.

Can I export the result to Excel?

After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.

Where are the formula sources?

Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • NIST/SEMATECH e-Handbook, 1.3.6.6.2: Uniform Distributionhttps://www.itl.nist.gov/div898/handbook/eda/section3/eda3662.htm
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors