Density CalculatorMeasure mass. Define volume.

Density calculators / Relative density & reference states

A clear measure of matter.

Density Temperature Correction Calculator

Estimate density change using a supplied constant volumetric expansion coefficient.

Your measurements & units

kg/m³
1/K
K

Starting values are editable examples. Confirm the sample, measurement basis and units. Dimension switching converts only the labelled geometry fields; other unit selectors describe the numbers you enter.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

ρtarget=ρreference/[1+β(Ttarget−Treference)].

Estimate density change using a supplied constant volumetric expansion coefficient.

  1. Confirm the sample, reference state, measurement basis and units.
  2. Enter actual measurements and compatible reference values.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Linear volume-expansion model with conserved mass and positive volume factor. Not ASTM D1250/API petroleum correction tables; phase changes and nonlinear property variation are excluded.

Density Temperature Correction: method and interpretation

Estimate density change using a supplied constant volumetric expansion coefficient. Linear volume-expansion model with conserved mass and positive volume factor. Not ASTM D1250/API petroleum correction tables; phase changes and nonlinear property variation are excluded.

Reference temperature and reference material are part of a relative-density definition. Specific gravity is a ratio and has no mass-density unit. API gravity is a particular petroleum convention; it is not a general temperature correction.

Confirm that the sample and reference inputs already use the required conditions. A constant expansion coefficient is a declared local approximation, whereas a full petroleum or real-fluid property method needs additional composition and state data.

Check the numbers

Density Temperature Correction Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Reference mass density = 850 kg/m³; Supplied volumetric expansion coefficient = 0.0007 1/K; Target minus reference temperature = 20 K.

OutputComputed result
Constant-coefficient temperature-adjusted density838.2643 kg/m³
Target / reference volume1.014 ratio
Mass density0.838264 g/cm³ or g/mL
Mass density52.331131 lb/ft³
Mass density0.030284 lb/in³
Mass density6.995655 lb/US gal
Mass density8.401431 lb/Imperial gal

How the stated input changes the result

ScenarioChanged input / basisResult
10 KTarget minus reference temperature844.09136 kg/m³
15 KTarget minus reference temperature841.167739 kg/m³
20 KTarget minus reference temperature838.2643 kg/m³
25 KTarget minus reference temperature835.380835 kg/m³
30 KTarget minus reference temperature832.51714 kg/m³
40 KTarget minus reference temperature826.848249 kg/m³

Unchanged inputs use: Reference mass density = 850 kg/m³; Supplied volumetric expansion coefficient = 0.0007 1/K; Target minus reference temperature = 20 K. Results retain the model limitations described above.

Common questions

What measurement or model limitation matters here?

Linear volume-expansion model with conserved mass and positive volume factor. Not ASTM D1250/API petroleum correction tables; phase changes and nonlinear property variation are excluded.

How are the example tables calculated?

Each row changes the labelled target minus reference temperature while retaining the other worked-example inputs. The table uses the same ρtarget=ρreference/[1+β(Ttarget−Treference)]. calculation as the form.

How do I use this density temperature correction calculator?

Estimate density change using a supplied constant volumetric expansion coefficient. ρtarget=ρreference/[1+β(Ttarget−Treference)].

Which units should I enter?

Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.

Are starting values measured material or reference data?

They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.

Can I export the result to Excel?

After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.

Where are the formula sources?

Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • OpenStax University Physics Volume 2: Thermal Expansion, volume expansion and constant-coefficient approximationhttps://openstax.org/books/university-physics-volume-2/pages/1-3-thermal-expansion
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors