Density CalculatorMeasure mass. Define volume.

Density calculators / Crystal & number density

A clear measure of matter.

Unit Cell Theoretical Density Calculator

Calculate theoretical orthorhombic unit-cell density from supplied lattice dimensions and formula-unit count.

Your measurements & units

g/mol
ångström
ångström
ångström

Starting values are editable examples. Confirm the sample, measurement basis and units. Dimension switching converts only the labelled geometry fields; other unit selectors describe the numbers you enter.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

ρ=Z M/(NA abc); NA=6.02214076×10²³ mol⁻¹.

Calculate theoretical orthorhombic unit-cell density from supplied lattice dimensions and formula-unit count.

  1. Confirm the sample, reference state, measurement basis and units.
  2. Enter actual measurements and compatible reference values.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Requires orthogonal cell axes; Z and molar mass must refer to matching formula units. No automatic crystal-structure recognition or occupancy correction.

Unit Cell Theoretical Density: method and interpretation

Calculate theoretical orthorhombic unit-cell density from supplied lattice dimensions and formula-unit count. Requires orthogonal cell axes; Z and molar mass must refer to matching formula units. No automatic crystal-structure recognition or occupancy correction.

The counted entity must match the molar mass. Atoms, molecules, formula units and mobile electrons are different entities. The Avogadro constant converts a defined amount of substance to a count; it does not identify the material or its electronic state.

A theoretical crystal density uses a supplied cell geometry, matching formula-unit count and occupancy assumptions. Actual defects, vacancies, temperature and porosity can make a specimen’s measured density differ from the ideal cell value.

Check the numbers

Unit Cell Theoretical Density Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Formula units per unit cell Z = 4 ; Matching formula-unit molar mass = 58.44 g/mol; Lattice a = 5.64 ångström; Lattice b = 5.64 ångström; Lattice c = 5.64 ångström.

OutputComputed result
Theoretical unit-cell density2,163.624967 kg/m³
Cell volume179.406144 ų
Mass density2.163625 g/cm³ or g/mL
Mass density135.070694 lb/ft³
Mass density0.078166 lb/in³
Mass density18.056325 lb/US gal
Mass density21.684743 lb/Imperial gal

How the stated input changes the result

ScenarioChanged input / basisResult
2.82 ångströmLattice a4,327.249933 kg/m³
4.23 ångströmLattice a2,884.833289 kg/m³
5.64 ångströmLattice a2,163.624967 kg/m³
7.05 ångströmLattice a1,730.899973 kg/m³
8.46 ångströmLattice a1,442.416644 kg/m³
11.28 ångströmLattice a1,081.812483 kg/m³

Unchanged inputs use: Formula units per unit cell Z = 4 ; Matching formula-unit molar mass = 58.44 g/mol; Lattice a = 5.64 ångström; Lattice b = 5.64 ångström; Lattice c = 5.64 ångström. Results retain the model limitations described above.

Common questions

What measurement or model limitation matters here?

Requires orthogonal cell axes; Z and molar mass must refer to matching formula units. No automatic crystal-structure recognition or occupancy correction.

How are the example tables calculated?

Each row changes the labelled lattice a while retaining the other worked-example inputs. The table uses the same ρ=Z M/(NA abc); NA=6.02214076×10²³ mol⁻¹. calculation as the form.

How do I use this unit cell theoretical density calculator?

Calculate theoretical orthorhombic unit-cell density from supplied lattice dimensions and formula-unit count. ρ=Z M/(NA abc); NA=6.02214076×10²³ mol⁻¹.

Which units should I enter?

Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.

Are starting values measured material or reference data?

They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.

Can I export the result to Excel?

After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.

Where are the formula sources?

Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • NIST: Redefining the Mole, silicon unit-cell counting relationhttps://www.nist.gov/si-redefinition/redefining-mole
  • NIST SP 330, Section 2: defining constants of the SIhttps://www.nist.gov/pml/special-publication-330/sp-330-section-2
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors