Density CalculatorMeasure mass. Define volume.

Density calculators / Population, plants & land

A clear measure of matter.

Stand Density Index Calculator

Calculate a hectare-based Reineke stand-density index from supplied stand measurements.

Your measurements & units

trees/ha
cm
same ha-based SDI units

Starting values are editable examples. Confirm the sample, measurement basis and units. Dimension switching converts only the labelled geometry fields; other unit selectors describe the numbers you enter.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

SDI=N(Dq/25.4)^1.605; relative SDI=SDI/supplied maximum.

Calculate a hectare-based Reineke stand-density index from supplied stand measurements.

  1. Confirm the sample, reference state, measurement basis and units.
  2. Enter actual measurements and compatible reference values.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Dq is quadratic mean diameter, not arithmetic mean. This is not a species-specific maximum database, mortality model or thinning recommendation.

Stand Density Index: method and interpretation

Calculate a hectare-based Reineke stand-density index from supplied stand measurements. Dq is quadratic mean diameter, not arithmetic mean. This is not a species-specific maximum database, mortality model or thinning recommendation.

Count and area must refer to the same boundary and observation period. Gross land area, net developable area, arable area and sampled habitat describe different denominators. No location-specific census or planning data are retrieved.

An observed density is distinct from an optimum stocking rate or legal development permission. Plant spacing gives an ideal repeated geometric arrangement; species, edges, access corridors and survival can change an actual planting plan.

Check the numbers

Stand Density Index Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Stand density = 500 trees/ha; Quadratic mean diameter = 20 cm; Supplied applicable maximum SDI = 1000 same ha-based SDI units.

OutputComputed result
Reineke stand-density index340.694429 ha-based SDI
Relative to supplied maximum34.069443 %

How the stated input changes the result

ScenarioChanged input / basisResult
10 cmQuadratic mean diameter111.998418 ha-based SDI
15 cmQuadratic mean diameter214.703122 ha-based SDI
20 cmQuadratic mean diameter340.694429 ha-based SDI
25 cmQuadratic mean diameter487.422534 ha-based SDI
30 cmQuadratic mean diameter653.117774 ha-based SDI
40 cmQuadratic mean diameter1,036.377976 ha-based SDI

Unchanged inputs use: Stand density = 500 trees/ha; Quadratic mean diameter = 20 cm; Supplied applicable maximum SDI = 1000 same ha-based SDI units. Results retain the model limitations described above.

Common questions

What measurement or model limitation matters here?

Dq is quadratic mean diameter, not arithmetic mean. This is not a species-specific maximum database, mortality model or thinning recommendation.

How are the example tables calculated?

Each row changes the labelled quadratic mean diameter while retaining the other worked-example inputs. The table uses the same SDI=N(Dq/25.4)^1.605; relative SDI=SDI/supplied maximum. calculation as the form.

How do I use this stand density index calculator?

Calculate a hectare-based Reineke stand-density index from supplied stand measurements. SDI=N(Dq/25.4)^1.605; relative SDI=SDI/supplied maximum.

Which units should I enter?

Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.

Are starting values measured material or reference data?

They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.

Can I export the result to Excel?

After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.

Where are the formula sources?

Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • USDA Forest Service: The Essential FVS, Section 7.3.2.1, stand-density index methodshttps://www.fs.usda.gov/sites/default/files/forest-management/essential-fvs.pdf
  • USDA Forest Service: Standview density-management diagrams and user-supplied maximum SDIhttps://research.fs.usda.gov/psw/products/dataandtools/standview
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors