Density CalculatorMeasure mass. Define volume.

Density calculators / Gas, air & temperature

A clear measure of matter.

Humid Air Density Calculator

Estimate moist-air density from station pressure, temperature and relative humidity.

Your measurements & units

kPa absolute
°C
%

Starting values are editable examples. Confirm the sample, measurement basis and units. Dimension switching converts only the labelled geometry fields; other unit selectors describe the numbers you enter.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

ρ=(p−pv)/(Rd T)+pv/(Rv T); pv=(RH/100) psaturation(T).

Estimate moist-air density from station pressure, temperature and relative humidity.

  1. Confirm the sample, reference state, measurement basis and units.
  2. Enter actual measurements and compatible reference values.
  3. Submit the form, then interpret the result with the assumptions and limits below.

0–40°C, ideal partial-pressure model over liquid water. No CIPM metrology corrections, enhancement factor, ice saturation or automatic altitude pressure.

Humid Air Density: method and interpretation

Estimate moist-air density from station pressure, temperature and relative humidity. 0–40°C, ideal partial-pressure model over liquid water. No CIPM metrology corrections, enhancement factor, ice saturation or automatic altitude pressure.

Gas density changes with absolute pressure, absolute temperature, composition and nonideal behavior. Gauge pressure must first be converted using the actual atmospheric reference. A supplied compressibility factor is not automatically a real-gas property calculation.

Standard atmosphere describes a reference profile rather than observed weather. Water and moist-air equations have explicit temperature and pressure boundaries. Cryogenic liquids, steam tables, salinity and supercritical properties cannot be inferred from an ideal-gas or pure-water relation.

Check the numbers

Humid Air Density Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Total station absolute pressure = 101.325 kPa absolute; Air temperature = 20 °C; Relative humidity = 50 %.

OutputComputed result
Ideal partial-pressure moist-air density1.198852 kg/m³
Water-vapor partial pressure1.169468 kPa
Dry-air partial pressure100.155532 kPa
Mass density0.001199 g/cm³ or g/mL
Mass density0.074842 lb/ft³
Mass density4.331129e-5 lb/in³
Mass density0.010005 lb/US gal
Mass density0.012015 lb/Imperial gal

How the stated input changes the result

ScenarioChanged input / basisResult
25 %Relative humidity1.201479 kg/m³
37.5 %Relative humidity1.200166 kg/m³
50 %Relative humidity1.198852 kg/m³
62.5 %Relative humidity1.197539 kg/m³
75 %Relative humidity1.196226 kg/m³
100 %Relative humidity1.193599 kg/m³

Unchanged inputs use: Total station absolute pressure = 101.325 kPa absolute; Air temperature = 20 °C; Relative humidity = 50 %. Results retain the model limitations described above.

Common questions

What measurement or model limitation matters here?

0–40°C, ideal partial-pressure model over liquid water. No CIPM metrology corrections, enhancement factor, ice saturation or automatic altitude pressure.

How are the example tables calculated?

Each row changes the labelled relative humidity while retaining the other worked-example inputs. The table uses the same ρ=(p−pv)/(Rd T)+pv/(Rv T); pv=(RH/100) psaturation(T). calculation as the form.

How do I use this humid air density calculator?

Estimate moist-air density from station pressure, temperature and relative humidity. ρ=(p−pv)/(Rd T)+pv/(Rv T); pv=(RH/100) psaturation(T).

Which units should I enter?

Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.

Are starting values measured material or reference data?

They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.

Can I export the result to Excel?

After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.

Where are the formula sources?

Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • Roland Stull, UBC: Meteorology for Scientists and Engineers, Chapter 1, equations 1.16–1.20https://www.eoas.ubc.ca/books/Practical_Meteorology/mse3/Ch01-Atmos.pdf
  • US National Weather Service: Vapor Pressure calculationhttps://www.weather.gov/media/epz/wxcalc/vaporPressure.pdf
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors