Density calculators / Gas, air & temperature
A clear measure of matter.
Humid Air Density Calculator
Estimate moist-air density from station pressure, temperature and relative humidity.
Your measurements & units
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
ρ=(p−pv)/(Rd T)+pv/(Rv T); pv=(RH/100) psaturation(T).
Estimate moist-air density from station pressure, temperature and relative humidity.
- Confirm the sample, reference state, measurement basis and units.
- Enter actual measurements and compatible reference values.
- Submit the form, then interpret the result with the assumptions and limits below.
0–40°C, ideal partial-pressure model over liquid water. No CIPM metrology corrections, enhancement factor, ice saturation or automatic altitude pressure.
Humid Air Density: method and interpretation
Estimate moist-air density from station pressure, temperature and relative humidity. 0–40°C, ideal partial-pressure model over liquid water. No CIPM metrology corrections, enhancement factor, ice saturation or automatic altitude pressure.
Gas density changes with absolute pressure, absolute temperature, composition and nonideal behavior. Gauge pressure must first be converted using the actual atmospheric reference. A supplied compressibility factor is not automatically a real-gas property calculation.
Standard atmosphere describes a reference profile rather than observed weather. Water and moist-air equations have explicit temperature and pressure boundaries. Cryogenic liquids, steam tables, salinity and supercritical properties cannot be inferred from an ideal-gas or pure-water relation.
Continue with: Ideal Gas Density Calculator · Air Density Calculator · Hydrogen Gas Density Calculator · Nitrogen Gas Density Calculator
Check the numbers
Humid Air Density Calculator: calculated examples
These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.
Worked example with stated inputs
Total station absolute pressure = 101.325 kPa absolute; Air temperature = 20 °C; Relative humidity = 50 %.
| Output | Computed result |
|---|---|
| Ideal partial-pressure moist-air density | 1.198852 kg/m³ |
| Water-vapor partial pressure | 1.169468 kPa |
| Dry-air partial pressure | 100.155532 kPa |
| Mass density | 0.001199 g/cm³ or g/mL |
| Mass density | 0.074842 lb/ft³ |
| Mass density | 4.331129e-5 lb/in³ |
| Mass density | 0.010005 lb/US gal |
| Mass density | 0.012015 lb/Imperial gal |
How the stated input changes the result
| Scenario | Changed input / basis | Result |
|---|---|---|
| 25 % | Relative humidity | 1.201479 kg/m³ |
| 37.5 % | Relative humidity | 1.200166 kg/m³ |
| 50 % | Relative humidity | 1.198852 kg/m³ |
| 62.5 % | Relative humidity | 1.197539 kg/m³ |
| 75 % | Relative humidity | 1.196226 kg/m³ |
| 100 % | Relative humidity | 1.193599 kg/m³ |
Unchanged inputs use: Total station absolute pressure = 101.325 kPa absolute; Air temperature = 20 °C; Relative humidity = 50 %. Results retain the model limitations described above.
Common questions
What measurement or model limitation matters here?
0–40°C, ideal partial-pressure model over liquid water. No CIPM metrology corrections, enhancement factor, ice saturation or automatic altitude pressure.
How are the example tables calculated?
Each row changes the labelled relative humidity while retaining the other worked-example inputs. The table uses the same ρ=(p−pv)/(Rd T)+pv/(Rv T); pv=(RH/100) psaturation(T). calculation as the form.
How do I use this humid air density calculator?
Estimate moist-air density from station pressure, temperature and relative humidity. ρ=(p−pv)/(Rd T)+pv/(Rv T); pv=(RH/100) psaturation(T).
Which units should I enter?
Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.
Are starting values measured material or reference data?
They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.
Can I export the result to Excel?
After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.
Where are the formula sources?
Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.
- Roland Stull, UBC: Meteorology for Scientists and Engineers, Chapter 1, equations 1.16–1.20https://www.eoas.ubc.ca/books/Practical_Meteorology/mse3/Ch01-Atmos.pdf
- US National Weather Service: Vapor Pressure calculationhttps://www.weather.gov/media/epz/wxcalc/vaporPressure.pdf
- NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors