Density CalculatorMeasure mass. Define volume.

Density calculators / Gas, air & temperature

A clear measure of matter.

Air Density at Altitude Calculator

Calculate standard dry troposphere temperature, pressure and density at a supplied height.

Your measurements & units

m

Starting values are editable examples. Confirm the sample, measurement basis and units. Dimension switching converts only the labelled geometry fields; other unit selectors describe the numbers you enter.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

T=288.15−0.0065h; p=101325(T/288.15)^5.255877; ρ=p/(287.053T).

Calculate standard dry troposphere temperature, pressure and density at a supplied height.

  1. Confirm the sample, reference state, measurement basis and units.
  2. Enter actual measurements and compatible reference values.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Ideal standard atmosphere from 0–11000 m geopotential height, not actual weather or aircraft performance. Real air at the same elevation may differ.

Air Density at Altitude: method and interpretation

Calculate standard dry troposphere temperature, pressure and density at a supplied height. Ideal standard atmosphere from 0–11000 m geopotential height, not actual weather or aircraft performance. Real air at the same elevation may differ.

Gas density changes with absolute pressure, absolute temperature, composition and nonideal behavior. Gauge pressure must first be converted using the actual atmospheric reference. A supplied compressibility factor is not automatically a real-gas property calculation.

Standard atmosphere describes a reference profile rather than observed weather. Water and moist-air equations have explicit temperature and pressure boundaries. Cryogenic liquids, steam tables, salinity and supercritical properties cannot be inferred from an ideal-gas or pure-water relation.

Check the numbers

Air Density at Altitude Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Geopotential height = 1000 m.

OutputComputed result
Standard troposphere dry-air density1.111642 kg/m³
Standard temperature281.65 K
Standard pressure89.874569 kPa absolute
Standard density ratio0.907463
Mass density0.001112 g/cm³ or g/mL
Mass density0.069398 lb/ft³
Mass density4.016062e-5 lb/in³
Mass density0.009277 lb/US gal
Mass density0.011141 lb/Imperial gal

How the stated input changes the result

ScenarioChanged input / basisResult
500 mGeopotential height1.167268 kg/m³
750 mGeopotential height1.139195 kg/m³
1000 mGeopotential height1.111642 kg/m³
1250 mGeopotential height1.084601 kg/m³
1500 mGeopotential height1.058067 kg/m³
2000 mGeopotential height1.00649 kg/m³

Unchanged inputs use: Geopotential height = 1000 m. Results retain the model limitations described above.

Common questions

What measurement or model limitation matters here?

Ideal standard atmosphere from 0–11000 m geopotential height, not actual weather or aircraft performance. Real air at the same elevation may differ.

How are the example tables calculated?

Each row changes the labelled geopotential height while retaining the other worked-example inputs. The table uses the same T=288.15−0.0065h; p=101325(T/288.15)^5.255877; ρ=p/(287.053T). calculation as the form.

How do I use this air density at altitude calculator?

Calculate standard dry troposphere temperature, pressure and density at a supplied height. T=288.15−0.0065h; p=101325(T/288.15)^5.255877; ρ=p/(287.053T).

Which units should I enter?

Use the unit printed beside each input or chosen in its selector. The dimension-unit switch converts only the length or area fields that carry it. Other quantities retain their printed units. Mass density has dimensions M L⁻³; a ratio, number per area or probability density is a different quantity.

Are starting values measured material or reference data?

They are editable worked-example inputs unless a specific source and reference condition are explicitly identified. Measure or obtain the properties appropriate to the actual sample, temperature and method.

Can I export the result to Excel?

After calculating, Export CSV saves numerical results and submitted inputs. CSV is a text table, not an Excel formula workbook or a certified test report.

Where are the formula sources?

Full source addresses are printed below as ordinary text. The equations, worked examples and comparison tables are contained in these pages and do not require an online data service.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • Roland Stull, UBC: Meteorology for Scientists and Engineers, Chapter 1, equations 1.16–1.20https://www.eoas.ubc.ca/books/Practical_Meteorology/mse3/Ch01-Atmos.pdf
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors